the pulse of the future directed energy incorporated PVX-2110 200v 50a pulse generator ? 0 to 200v pulse output ? 10kw peak output power ? <100ns rise and fall times ? <200ns to 2ms pulse width ? 0 to 50khz pulse repetition frequency ? protected against arcs, shorts and load transients ? integral voltage and current monitor outputs ? optimized to drive loads from 1 ? ? ? ? to 25 ? ? ? ? the PVX-2110 high power pulse generator (pulsed volt- age source) is designed for pulsing low impedance loads (from 1 ? to 25 ?) at up to 200v and 50a, with pulse widths from 200ns to 2ms . the exceptional pulse fidelity of the PVX-2110 will optimize the performance of any system in which it is used. the PVX-2110 can deliver up to 10kw of peak output power and 5kw of average output power, making it well suited for use in materials testing and processing, semi- conductor testing and characterization, and other test and measurement and r&d applications. the PVX-2110 requires a ttl gate signal and high volt- age dc power supply inputs. the output pulse width and frequency are controlled by the gate signal. the pulse out- put voltage is controlled by the amplitude of the input dc power supply. the PVX-2110 features front panel indicator leds to monitor the status of the pulse generator. front panel volt- age and current monitors provide a straightforward means to view the output voltage and current waveforms in real- time, eliminating the need for an external high voltage os- cilloscope probe. the output cable supplied with the unit is an innovative custom designed multi-coaxial cable with an impedance of 5 ?. the design of this cable maintains the fidelity of the output pulse without introducing pulse distortion or ringing, and provides a convenient means of connecting the pulse generator to the load. the PVX-2110 has over-current detection and shut-down circuitry to protect the pulse generator from potential dam- age due to over-current conditions such as arcs and shorts in the load or interconnect cable. if an over-current condi- tion is detected, the output pulse is truncated for 10 milli- seconds. the pulse generator then automatically re- enables the output, and will continue pulsing, unless the over-current condition persists. it is also protected against operation at excessive pulse widths or frequencies. the pulse generator is a direct-coupled, air-cooled solid- state design, offering fast pulse rise and fall times, low power dissipation, and virtually no over-shoot, under-shoot or ringing. all control and protection logic circuitry, support power, energy storage and output network are incorporated into the PVX-2110. it is connected directly to the load, and does not require series or shunt resistors, impedance- matching networks between the pulse generator and the load, or additional energy storage (capacitor banks). all of this is taken care of within the PVX-2110.
the pulse of the future directed energy, inc. an ixys company 2401 research blvd., suite 108 fort collins, co usa 80526 970-493-1901 fax: 970-493-1903 email: deiinfo@directedenergy.com web: http://www.directedenergy.com specifications (all specifications measured into a 5 ? load connected with 4 feet (~1.2m) 5 ? cable provided with the PVX-2110) doc #9200-0216 rev 3 ? directed energy, inc. 2000 output output voltage polarity positive or negative, factory configured maximum value 200 volts minimum value 0 volts means of adjustment controlled by power supply input voltage maximum output current 50a peak, 25a average (1) pulse rise and fall time <100ns (10% to 90%) pulse width <200ns to 2ms, controlled by input gate pulse recurrence frequency (prf) single shot to 50khz, controlled by input gate max. peak output power 10,000w (2) max. duty cycle 50% droop (at 50a output current) <5% @ 1ms pulse width, <10% @ 2ms pulse width over/undershoot <5% jitter <10ns shot-to-shot output connector & cable type n, with 4 feet (~1.2m) 5 ? coaxial cable input dc voltage input voltage polarity positive or negative (user-supplied) (4) maximum value 200 volts minimum value 0 volts maximum input power 5,000w input dc connector type n, rear panel gate gate source +5v 1v into 50 ? input gate connector bnc, front panel voltage & current monitors voltage monitor 50:1 into 50 ? , accuracy typically within 3% of the actual output voltage voltage monitor connector bnc, front panel current monitor 10a/v into 50 ? , accuracy typically within 3% of the actual output current current monitor connector bnc, front panel general support power 90vac to 240vac, 50/60hz dimensions (excluding connec- tors) 19? w x 5.2? h x 16? d (48.25cm w x 13.2cm h x 41cm d) weight (approximate) 18 lbs. (8.2 kilograms) specifications subject to change without notice max. average output power 5,000w (3) 200ns minimum pulse width, 200v output (100ns/div horizontal scale, 50v/div vertical scale) <50ns rise time, 200v output (25ns/div horizontal scale, 50v/div vertical scale) typical output waveform, 200v (10s/div horizontal scale, 50v/div vertical scale) 50khz, 50% duty cycle, 200v output (8 ? ? ? ? load, 10s/div horizontal scale, 50v/div vertical scale) (1) when driving loads with impedances <5 ? , the output voltage must be limited to <200v, so that the peak output current (v/r) does not exceed 50a, and the maximum average current (defined as i x duty cycle) does not exceed 25a. (2) peak output power is defined as v x i during the output pulse. (3) average output power is defined as v x i x duty cycle. (4) input dc power supply must be the same polarity as the PVX-2110 (i.e. a positive output PVX-2110 requires a positive high voltage dc input).
|